Drug Database
AL

Albunex (Albunex / Infoson)

✓ Approved

Alliance Pharma PLC · Small Molecule · Small Molecule

What is Albunex?

Albunex is a small molecule developed by Alliance Pharma PLC. It is approved for therapeutic indications via injectable (others) or intraarterial injection.

Drug Profile

Brand NamesAlbunex, Infoson
CompanyAlliance Pharma PLC
Drug ClassSmall Molecule, Imaging Agents
RouteInjectable (Others), Intraarterial Injection
StatusApproved

Therapeutic Indications

Albunex is developed for 2 unique indications across 2 therapeutic areas.

Therapeutic AreaConditionPhase
Cardiac disordersArteriosclerosis coronary artery✓ Approved
Surgical and medical proceduresGynaecological disorder prophylaxisBLA/NDA

Related Research Articles

PubMedPharmaceutics2022-06-25

Microbubbles Stabilized by Protein Shell: From Pioneering Ultrasound Contrast Agents to Advanced Theranostic Systems.

Rudakovskaya Polina G PG, Barmin Roman A RA, Kuzmin Pavel S PS, Fedotkina Elena P EP et al.

Ultrasound is a widely-used imaging modality in clinics as a low-cost, non-invasive, non-radiative procedure allowing therapists faster decision-making. Microbubbles have been used as ultrasound contrast agents for decades, while recent attention has been attracted to consider them as stimuli-responsive drug delivery systems. Pioneering microbubbles were Albunex with a protein shell composed of human serum albumin, which entered clinical practice in 1993. However, current research expanded the set of proteins for a microbubble shell beyond albumin and applications of protein microbubbles beyond ultrasound imaging. Hence, this review summarizes all-known protein microbubbles over decades with a critical evaluation of formulations and applications to optimize the safety (low toxicity and high biocompatibility) as well as imaging efficiency. We provide a comprehensive overview of (1) proteins involved in microbubble formulation, (2) peculiarities of preparation of protein stabilized microbubbles with consideration of large-scale production, (3) key chemical factors of stabilization and functionalization of protein-shelled microbubbles, and (4) biomedical applications beyond ultrasound imaging (multimodal imaging, drug/gene delivery with attention to anticancer treatment, antibacterial activity, biosensing). Presented critical evaluation of the current state-of-the-art for protein microbubbles should focus the field on relevant strategies in microbubble formulation and application for short-term clinical translation. Thus, a protein bubble-based platform is very perspective for theranostic application in clinics.

PubMedThe Journal of the Acoustical Society of America2013-05-10

Dynamical analysis of the nonlinear response of ultrasound contrast agent microbubbles.

Carroll James M JM, Calvisi Michael L ML, Lauderbaugh Leal K LK

The nonlinear response of spherical ultrasound contrast agent microbubbles is investigated to understand the effects of common shells on the dynamics. A compressible form of the Rayleigh-Plesset equation is combined with a thin-shell model developed by Lars Hoff to simulate the radial response of contrast agents subject to ultrasound. The responses of Albunex, Sonazoid, and polymer shells are analyzed through the application of techniques from dynamical systems theory such as Poincaré sections, phase portraits, and bifurcation diagrams to illustrate the qualitative dynamics and transition to chaos that occurs under certain changes in system parameters. Corresponding calculations of Lyapunov exponents provide quantitative data on the system dynamics. The results indicate that Albunex and polymer shells sufficiently stabilize the response to prevent transition to the chaotic regime throughout typical clinical ranges of ultrasound pressure and frequency. By contrast, Sonazoid shells delay the onset of chaos relative to an unshelled bubble but do not prevent it. A contour plot identifying regions of periodic and chaotic behavior over clinical ranges of ultrasound pressure and frequency is provided for Sonazoid. This work characterizes the nonlinear response of various ultrasound contrast agents, and shows that shell properties have a profound influence on the dynamics.

PubMedOntario health technology assessment series2010-01-01

Stress echocardiography with contrast for the diagnosis of coronary artery disease: an evidence-based analysis.

Medical Advisory Secretariat

In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities.After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website).The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.htmlSINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY WITH CONTRAST FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based Analysis64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based AnalysisCARDIAC MAGNETIC RESONANCE IMAGING FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisPease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website:POSITRON EMISSION TOMOGRAPHY FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based AnalysisMAGNETIC RESONANCE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: an Evidence-Based AnalysisThe Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled:The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 OBJECTIVE: The objective of this report is to compare echocardiography (ECHO) performed with microsphere contrast agents (contrast echocardiography) to ECHO performed without contrast and to single photon emission computed tomography (SPECT). CONTRAST ECHO: Contrast agents for ECHO have been available since the technology was first introduced in the 1990s. Composed of tiny 'microbubbles' of an inert gas encapsulated within a lipid, protein, or polymer coat, these agents act to scatter incident ultrasound waves at the gas/liquid interface to increase the strength of a returning ECHO signal. When injected into a patient's arm, they are transported throughout even the smallest capillaries to greatly enhance the blood pool signal, which would otherwise appear black on conventional two dimensional ECHO. The enhanced signal then helps cardiologists to determine what parts of the patient's heart muscle are poorly perfused. The first commercially available microsphere contrast agent was Albunex, which received approval by the Food and Drug Administration in the United States in 1994. This original microsphere agent was limited by its rapid gas volume loss which caused a decline in the ultrasound signal. It worked well in the right chambers of the heart, but dissolved when passing through the pulmonary capillaries and so was unable to provide contrast in the left side. Second generation agents employed different gases that prolonged the life of the microbubbles within the circulation and increased the reproducibility of results. Today, the most common use for contrast ECHO is to enhance the definition of the left ventricular (LV) endocardial border for cases of LV opacification. The aim of contrast ECHO is to provide better quantification of LV volume and assessment of LV wall motion than ECHO alone. The newest area of development in the research of contrast ECHO is myocardial perfusion assessment, also known as myocardial contrast ECHO. Theoretically, since myocardial ischemia and infarction affect both perfusion and contractility (wall motion), contrast ECHO could be an ideal non-invasive imaging test as it could assess both perfusion and contractility, simultaneously and in real time. Notably, critically ill patients on ventilators and those with lung problems are more likely to generate poor or 'suboptimal' echocardiograms than other patients, as are obese patients and those who've undergone recent chest operations. Contrast agents can potentially be used in 10% to 15% of all studies and in approximately 33% of stress tests due to from such suboptimal echocardiograms. Stress can be induced either pharmaceutically (e.g., through dobutamine, dipyrimidamole, adenosine) or with exercise. Generally, contrast agents are used more in pharmaceutical stress echocardiograms than in exercise stress echocardiograms. EVIDENCE-BASED ANALYSIS: This MAS analysis sought to address the following research questions: Is contrast ECHO more effective than 99-technetium SPECT in terms its ability to detect CAD?What is the effectiveness of contrast ECHO in assessing patients with suboptimal echocardiograms?Is contrast ECHO safe compared to other cardiac imaging modalities?Is contrast ECHO cost-effective compared to other cardiac imaging modalities? Literature searches were performed on June 22, 2009 and July 27, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2004 until June 30, 2009. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria; full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. Systematic reviews, meta-analyses, randomized controlled trials, prospective observational studies, retrospective analysesMinimum sample size of 20 enrolled patients (human only)The contrast agent used in the study must be licensed by Health CanadaComparison to reference standard (coronary angiography for the diagnosis of coronary artery disease)Reporting accuracy data on individual patients (rather than accuracy data stratified by segments of the heart)English language Non-systematic reviews, case reportsGrey literature (e.g. conference abstracts) Accuracy outcomes (sensitivity, specificity, positive predictive value, negative predictive value)Adverse eventsCosts Twenty-three observational studies were identified that assessed the diagnostic accuracy of contrast ECHO for the diagnosis of CAD. All of these studies used stress ECHO with contrast. In addition, nine retrospective chart reviews were identified, which assessed the safety of contrast ECHO at rest or stress. Based on the results of these studies the following conclusions were made: Stress ECHO with contrast has a higher diagnostic accuracy in the diagnosis of CAD than stress ECHO (without contrast).Stress ECHO with contrast seems to have a similar diagnostic accuracy to 99 technetium SPECT.The addition of contrast to ECHO in patients with suboptimal ECHO results significantly improves interpretability of the results.There is not a statistically significantly higher mortality rate in patients who receive contrast compared to those who do not.

PubMedUltrasonics2009-04-07

Optimal dosage of ultrasound contrast agent for ultrasound surgery: thermal effect of linear plane wave.

Seo Jongbum J

The optimal dosage of ultrasound contrast agent model for ultrasound surgery was explored. A specific ultrasound contrast agent Albunex was chosen for simulation. The model was developed based on a dilute bubbly liquid model proposed by Ye and Ding [Z. Ye, L. Ding, Acoustic dispersion and attenuation relations in bubbly mixture, J. Acoust. Soc. Am. 98 (3) (1995) 1629-1636]. The numerical simulation suggests that 2 MHz is more efficient than 1 MHz to thermally treat cancer in deep tissue with the optimal dosage of 3 ml. On the other hand, the simulation also suggests 3 MHz center frequency with the optimal dosage of 1.6 ml is adequate for prostate cancer treatment with transrectal equipment. The simulation is expected to valid up to 2 MPa incident pressure due to the limitation of the linearized UCA model. Even though it is developed from a single ultrasound contrast agent, this model is expected to be useful for any ultrasound contrast agent as long as the necessary parameters are provided.

PubMedUltrasonics2006-07-21

Study on the multiple scattering effects of ultrasound contrast agents.

Chen Jiusheng J, Zhu Zhemin Z

In this paper, the multiple scattering of interacting encapsulated microbubbles in suspensions is calculated using two novel approaches--Kargl's effective medium approach and Ye and Ding's approach of 2nd-order correction. Two types of contrast agents with bubbles of different sizes and concentrations are chosen for our numerical simulations. One is Albunex, which is depicted by Church and has a size range of several microns, and the other is sodium laureate solution (before fractionation) described by Soetanto and Chan and has an average size of 35.5 microm. The numerical results from these two approaches are compared with that from the linear approximation. It is found that the multiple scattering effects on attenuation and dispersion of sound in suspensions are evident in the cases of high bubble volume fractions, basically greater than the order of 1 x 10(-4), and much more obvious for larger bubbles with average size of tens of microns.

PubMedUltrasound in medicine & biology2006-06-21

Biological and environmental factors affecting ultrasound-induced hemolysis in vitro: 5. Temperature.

Miller Morton W MW, Church Charles C CC, Labuda Cecille C, Mazza Salvatore S et al.

This research project tested the hypothesis that cold-equilibrated (approximately 0 degrees C) human erythrocytes in vitro in the presence of an ultrasound contrast agent (Albunex) will undergo greater ultrasound-induced hemolysis than physiologically equilibrated (37 degrees C) human erythrocytes in vitro because of a temperature-related transition in membrane fluidity leading to increased fragility. First, it was shown that cold-equilibrated erythrocytes are more susceptible to mechanically induced hemolysis than physiologically equilibrated erythrocytes. Second, when adjustments were made for (1) temperature-dependent efficiencies of a 1-MHz transducer (200 micros pulse length, 20 ms interpulse interval, 30 s exposure duration) such that when cold or physiological temperatures were employed, there were equivalent acoustic outputs in terms of peak negative pressure (MPa P-) and (2) comparable viscosities of the 0 and 37 degrees C blood plasmas, the cold (approximately 0 degrees C) erythrocytes displayed substantially greater amounts of ultrasound-induced hemolysis than the physiological (37 degrees C) erythrocytes. The data supported the hypothesis.

+188 more articles available with a free account

Sign up free to view all articles →

Ask about Albunex